Specifications |
Digital Input |
Output Channels |
8 |
Output Type |
Power Relay, Form A (SPST N.O.) |
Operating Voltage Range |
250 VAC/30 VDC |
Max. Load Current |
5.0A/channel at 25 °C |
Operate Time |
6 ms (Typical) |
Release Time |
3 ms (Typical) |
Electrical Life (Resistive Load) |
VDE |
5A 250 VAC 30,000 ops (10 ops/minute) at 75 °C 5A 30 VDC 70,000 ops (10 ops/minute) at 75 °C |
UL |
5A 250 VAC/30 VDC 6,000 ops. 3A 250 VAC/30 VDC 100,000 ops. |
Mechanical Life |
20,000,000 ops. at no load (300 ops./minute) |
System |
CPU |
16-bit CPU |
SRAM |
512 KB |
Flash Memory |
512 KB |
EEPROM |
16 KB |
Watchdog |
Yes |
Communication |
PoE Ethernet Port |
10 / 100 Base-TX (With Link, Activity LED Indicator) and automatic MDI/MDI-X |
2 Way Isolation |
I/O |
10 / 100 Base-TX (With Link, Activity LED Indicator) and automatic MDI/MDI-X |
EMS Protection |
ESD (IEC 61000-4-2) |
4 kV Contact for each terminal |
EFT (IEC 61000-4-4) |
+/-2 kV for Power |
LED Indicators |
PoE |
PoE On |
L1 |
System Running |
L2 |
Ethernet Link/Act |
L3 |
Ethernet 10/100M Speed |
Power Requirements |
Reserve Polarity Protection |
Yes |
Powered from terminal block |
Yes, 12 ~ 48 VDC |
Powered from PoE |
Yes, IEEE 802.3af, Class1 |
Consumption |
5.3 W |
Mechanical |
Dimensions (W x H x D) |
72 mm x 123 mm x 35 mm |
Installation |
DIN-Rail or Wall mounting |
Environment |
Operating Temperature |
-25 ~ +75 °C |
Storage Temperature |
-30 ~ +80 °C |
Humidity |
10 ~ 90% RH, non-condensing |
Software Specifications |
Functions |
Rule Configuration Website |
Access Web server on WISE controllers to edit and upload logic rules through web browser. |
36 IF-THEN-ELSE Logic Rules |
3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions |
48 Internal Registers |
Hold temporary variables and read/write data via Modbus/TCP address. |
12 Timers |
Delay / Timing functions. |
12 Emails |
Send Email messages to pre-set Email receivers. |
12 CGI Commands |
Send pre-set CGI commands. |
12 Recipes |
Set up THEN/ELSE action groups. |
8 P2P remote modules |
Set up the connection information for the remote WISE modules. |
Modbus/TCP Protocol |
Real time control and monitoring I/O channels and system status of controllers via SCADA software. |
IF Conditions |
Internal Register |
=?>?=?<=(value) |
DO Counter |
=?>?=?<=(value)?Change |
Timer |
Timeout?Not Timeout |
P2P |
DI?AI?DI counter?DO counter?IR |
Rule Status |
Enable?Disable |
THEN / ELSE Actions |
DO Channel |
ON?OFF?Pulse Output |
Internal Register |
Change the value |
DO Counter |
Reset |
Timer |
Start?Stop |
Email |
Send |
CGI Commands |
Recipe |
Execute |
P2P |
DO(On/Off)?AO?IR |
Rule Status |
Enable?Disable |