Specifications |
Digital Input |
Input Channels |
8 |
Input Type |
Wet Contact (Sink, Source) |
On Voltage Level |
+10 VDC ~ +50 VDC |
Off Voltage Level |
+4 VDC Max |
Input Impedance |
10 kO |
Counters |
Max. Count |
65535 (16 bits) |
Max. Input Frequency |
50 Hz |
Min. Pulse Width |
10 ms |
Overvoltage Protection |
+70 VDC |
Digital Output |
Output Channels |
8 |
Output |
Type Open Collector (Source) |
Max Load Current |
650 mA/channel at 25 °C |
Output Voltage |
+10 VDC ~ +40 VDC |
Overvoltage Protection |
47 VDC |
Overload Protection |
- |
Short Circuit Protection |
Yes |
System |
CPU |
16-bit CPU |
SRAM |
512 KB |
Flash Memory |
512 KB |
EEPROM |
16 KB |
Watchdog |
Yes |
Communication |
PoE Ethernet Port |
10 / 100 Base-TX (With Link, Activity LED Indicator) and Automatic MDI/MDI-X |
2 Way Isolation |
I/O |
3750 Vrms |
EMS Protection |
ESD (IEC 61000-4-2) |
4 kV Contact for each terminal |
EFT (IEC 61000-4-4) |
+/-2 kV for Power |
LED Indicators |
PoE |
PoE On |
L1 |
System Running |
L2 |
Ethernet Link/Act |
L3 |
Ethernet 10/100M Speed |
Power Requirements |
Reserve Polarity Protection |
Yes |
Powered from terminal block |
Yes, 12 ~ 48 VDC |
Powered from PoE |
Yes, IEEE 802.3af, Class1 |
Consumption |
4.3 W |
Mechanical |
Dimensions (W x H x D) |
72 mm x 123 mm x 35 mm |
Installation |
DIN-Rail or Wall mounting |
Environment |
Operating Temperature |
-25 ~ +75 °C |
Storage Temperature |
-30 ~ +80 °C |
Humidity |
10 ~ 90% RH, non-condensing |
Functions |
Rule Configuration Website |
Access Web server on WISE controllers to edit and upload logic rules through web browser. |
36 IF-THEN-ELSE Logic Rules |
3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions |
48 Internal Registers |
Hold temporary variables and read/write data via Modbus/TCP address. |
12 Timers |
Delay / Timing functions. |
12 Emails |
Send Email messages to pre-set Email receivers. |
12 CGI Commands |
Send pre-set CGI commands. |
12 Recipes |
Set up THEN/ELSE action groups. |
8 P2P remote modules |
Set up the connection information for the remote WISE modules. |
Modbus/TCP Protocol |
Real time control and monitoring I/O channels and system status of controllers via SCADA software. |
IF Conditions |
DI Channel |
ON,OFF,ON to OFF,OFF to ON,Change |
Internal Register |
=,>,<,>=,<=(value) |
DI Counter |
=,>,<,>=,<=(value),Change |
DO Counter |
- |
Timer |
Timeout,Not Timeout |
P2P |
DI,AI,DI counter,DO counter,IR |
Rule Status |
Enable,Disable |
THEN / ELSE Actions |
DO Channel |
ON,OFF,Pulse Output |
Internal Register |
Change the value |
DI Counter |
Reset |
DO Counter |
- |
Timer |
Start,Stop |
Email |
Send |
CGI |
Commands |
Recipe |
Execute |
P2P |
DO(On/Off),AO,IR |
Rule Status |
Enable,Disable |