| Specifications |
| Digital Input |
| Input Channels | 8 (Differential) |
| Input Type | Wet Contact (Sink, Source) |
| On Voltage Level | +10 VDC ~ +50 VDC |
| Off Voltage Level | +4 VDC Max |
| Input Impedance | 10 kO |
Counters | Max. Count | 65535 (16 bits) | | Max. Input Frequency | 50 Hz |
| Min. Pulse Width | 10 ms |
| Over Voltage Protection | +70 VDC |
| Digital Output |
| Output Channels | 8 |
| Output Type | Isolated Open Collector (Sink) |
| Max. Load Current | 300 mA/channel at 25 °C Direct drive power relay module |
| Output Voltage | +10 VDC ~ +40 VDC |
| Overvoltage Protection | 60 VDC |
| Overload Protection | 1.1 A |
| Short-circuit Protection | Yes |
| System |
| CPU | 16-bit CPU |
| SRAM | 512 KB |
| Flash Memory | 512 KB |
| EEPROM | 16 KB |
| Watchdog | Yes |
| Communication |
| PoE Ethernet Port | 10/100 Base-TX (With Link, Activity LED Indicator) and automatic MDI/MDI-X |
| 2-way Isolation |
| I/O | 3750 VDC |
| EMS Protection |
| ESD (IEC 61000-4-2) | 4 kV Contact for each terminal |
| EFT (IEC 61000-4-4) | +/-2 kV for Power |
| LED Indicators |
| PoE | PoE On |
| L1 | System Running |
| L2 | Ethernet Link/Act |
| L3 | Ethernet 10/100M Speed |
| Power Requirements |
| Reserve Polarity Protection | Yes |
| Powered from terminal block | Yes, 12 ~ 48 VDC |
| Powered from PoE | Yes, IEEE 802.3af, Class1 |
| Consumption | 4.3 W |
| Mechanical |
| Dimensions (W x H x D) | 123 mm x 72 mm x 35 mm |
| Installation | DIN-Rail or Wall mounting |
| Environment |
| Operating Temperature | -25°C ~ +75 °C |
| Storage Temperature | -30°C ~ +80 °C |
| Relative Humidity | 5 ~ 90% RH, non-condensing |
| Software Specifications |
| Functions |
| Rule Configuration Website | Access Web server on WISE controllers to edit and upload logic rules through web browser. |
36 IF-THEN-ELSE Logic Rules | 3 IF conditions with AND or OR operators | | 3 THEN actions and 3 ELSE actions |
| 48 Internal Registers | Hold temporary variables and read/write data via Modbus/TCP address. |
| 12 Timers | Delay / Timing functions. |
| 12 Emails | Send Email messages to pre-set Email receivers. |
| 12 CGI Commands | Send pre-set CGI commands. |
| 12 Recipes | Set up THEN/ELSE action groups. |
| 8 P2P remote modules | Set up the connection information for the remote WISE modules. |
| Modbus/ TCP Protocol | Real time control and monitoring I/O channels and system status of controllers via SCADA software. |
| IF Conditions |
| DI Channel | ON, OFF, ON to OFF, OFF to ON, Change |
| Internal Register | =, >, <, >=, <=(value) |
| DI Counter | =, >, <, >=, <=(value), Change |
| DO Counter |
| Timer | Timeout, Not Timeout. |
| P2P | DI, AI, DI counter, DO counter, IR |
| Rule Status | Enable, Disable. |
| THEN / ELSE Actions |
| DO Channel | ON, OFF, Pulse Output |
| Internal Register | Change the value |
| DI Counter | Reset |
| DO Counter |
| Timer | Start, Stop |
| Email | Send |
| CGI Commands |
| Recipe | Execute |
| P2P | DO(On/Off), AO, IR |
| Rule Status | Enable, Disable. |