Specifications |
CPU Module |
CPU | 16-bit CPU |
SRAM | 768 KB |
Flash | 512 KBn |
microSD Expansio | Yes, can support 1 or 2 GB microSD |
RTC (Real Time Clock) | RTC Provide seconds, minutes, hours, date of week/month; month and year |
Watchdog Timers | Yes (0.8 second) |
Communication Ports |
Ethernet | RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators) |
COM 1 | RS-232 (TxD, RxD, RTS, CTS, GND), non-isolated, Speed: 115200 bps max. |
COM 2 | RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max. |
LED Indicators |
System LED | Yes (Red) |
Ethernet Link LED | Yes (Green : Ethernet link detected, Flashing Green : Ethernet packet received) |
Hardware Expansion |
I/O Expansion Bus | Yes |
SMS Function |
Frequency Band | Quad-band 850/900/1800/1900 MHz |
Mode | Text and Unicode mode |
Power Requirements |
Protection | Power Reverse Polarity Protection |
Frame Ground | Yes (for ESD Protection) |
Input Range | 12 ~ 48 VDC |
Redundant Power Input | Yes |
Power Consumption | 2.0 W |
Mechanical |
Dimensions (W x H x D) | 91 mm x 132 mm x 52 mm |
Installation | DIN-Rail |
Environment |
Operating Temperature | -25 ~ +75 °C |
Storage Temperature | -30 ~ +80 °C |
Ambient Relative Humidity | 10 ~ 90% RH (non-condensing) |
|
Software Specs |
Functions |
Rule Configuration Website | Access Web server on WISE controllers to edit and upload logic rules through web browser. |
36 IF-THEN-ELSE Logic Rules | 3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions |
48 Internal Registers | Hold temporary variables and read/write data via Modbus/TCP address. |
12 Timers | Delay / Timing functions. |
12 Schedules | Setup prescheduled routine tasks. |
12 Emails | Send Email messages to pre-set Email receivers. |
12 SMS | Send SMS to pre-set mobile phone numbers. |
12 CGI | Commands Send pre-set CGI commands. |
12 Recipes | Set up THEN/ELSE action groups. |
Data Logger | Set up the Data Logger configuration, include the data record format, and data file sending operation. |
Modbus TCP/RTU Protocol | Real time control and monitoring I/O channels and system status of controllers via SCADA software. |
IF Conditions |
DI Channel | ON,OFF,ON to OFF,OFF to ON,Change |
AI Channel | =, >, <, >=,<=(value) |
Internal Register | - |
DI Counter | =, >, <, >=, <=(value)?Change |
Timer | Timeout, Not Timeout |
Schedule | In Range, Out of Range |
SMS Command | 0, 1 |
Rule Status | Enable, Disable |
THEN / ELSE Actions |
DO Channel | ON, OFF, Pulse Output (apply to XW-Board only) |
AO Channel | Change the value |
Internal Register |
DI Counter | Reset |
Timer | Start, Reset |
Schedule | Enable, Disable |
Email | Send |
SMS Alarm |
CGI Commands |
Recipe | Execute |
Data Logger | Start, Stop, One-Time Log |
Rule Status | Enable, Disable |