Specifications |
CPU Module |
CPU |
16-bit CPU |
SRAM |
768 KB |
Flash |
512 KBn |
microSD Expansio |
Yes, can support 1 or 2 GB microSD |
RTC (Real Time Clock) |
RTC Provide seconds, minutes, hours, date of week/month; month and year |
Watchdog Timers |
Yes (0.8 second) |
Communication Ports |
Ethernet |
RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators) |
COM 1 |
RS-232 (TxD, RxD, RTS, CTS, GND), non-isolated, Speed: 115200 bps max. |
COM 2 |
RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max. |
LED Indicators |
System LED |
Yes (Red) |
Ethernet Link LED |
Yes (Green : Ethernet link detected, Flashing Green : Ethernet packet received) |
Hardware Expansion |
I/O Expansion Bus |
Yes |
SMS Function |
Frequency Band |
Quad-band 850/900/1800/1900 MHz |
Mode |
Text and Unicode mode |
Power Requirements |
Protection |
Power Reverse Polarity Protection |
Frame Ground |
Yes (for ESD Protection) |
Input Range |
12 ~ 48 VDC |
Redundant Power Input |
Yes |
Power Consumption |
2.0 W |
Mechanical |
Dimensions (W x H x D) |
91 mm x 132 mm x 52 mm |
Installation |
DIN-Rail |
Environment |
Operating Temperature |
-25 ~ +75 °C |
Storage Temperature |
-30 ~ +80 °C |
Ambient Relative Humidity |
10 ~ 90% RH (non-condensing) |
|
Software Specs |
Functions |
Rule Configuration Website |
Access Web server on WISE controllers to edit and upload logic rules through web browser. |
36 IF-THEN-ELSE Logic Rules |
3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions |
48 Internal Registers |
Hold temporary variables and read/write data via Modbus/TCP address. |
12 Timers |
Delay / Timing functions. |
12 Schedules |
Setup prescheduled routine tasks. |
12 Emails |
Send Email messages to pre-set Email receivers. |
12 SMS |
Send SMS to pre-set mobile phone numbers. |
12 CGI |
Commands Send pre-set CGI commands. |
12 Recipes |
Set up THEN/ELSE action groups. |
Data Logger |
Set up the Data Logger configuration, include the data record format, and data file sending operation. |
Modbus TCP/RTU Protocol |
Real time control and monitoring I/O channels and system status of controllers via SCADA software. |
IF Conditions |
DI Channel |
ON,OFF,ON to OFF,OFF to ON,Change |
AI Channel |
=, >, <, >=,<=(value) |
Internal Register |
- |
DI Counter |
=, >, <, >=, <=(value)?Change |
Timer |
Timeout, Not Timeout |
Schedule |
In Range, Out of Range |
SMS Command |
0, 1 |
Rule Status |
Enable, Disable |
THEN / ELSE Actions |
DO Channel |
ON, OFF, Pulse Output (apply to XW-Board only) |
AO Channel |
Change the value |
Internal Register |
DI Counter |
Reset |
Timer |
Start, Reset |
Schedule |
Enable, Disable |
Email |
Send |
SMS Alarm |
CGI Commands |
Recipe |
Execute |
Data Logger |
Start, Stop, One-Time Log |
Rule Status |
Enable, Disable |