Indicator S320A-1-ST
S320A-1-ST
S320A-1-ST

S320A-1-ST

review
0
0
5
Price: $271.40
No inventory, please confirm shipping time
Part number:S320A-1-ST
Quantity pricing
Quantity
Price
  • 3 - 4
  • $265.97
  • 5 - 9
  • $260.54
  • 10 - 24
  • $252.40
  • 25 - 49
  • $241.55
  • 50 - 99
  • $238.83
  • 100+
  • $233.40
3 ½ digit indicator, V / I input, 2 relay alarms, 96x96 mm, power supply 115 / 230 Vac

S-Line Series is a high performance compact/modular indicators / totalizers family. This series offers scalable display with 4, 6, 8, 4+7 digits in multiple visualization mode (real-time, integrated, totalized measured values). S-Line indicators support universal input (analog, digital, by sensor) and restransmitted output mA, V standard. Concerning power supply they ensure an extended option range options: 80-265 Vac; 10-40 Vdc / 19-28 Vac; power transducers. Accuracy class reach 0,1% with 14-16 bit A/D conversion. Optionally S-Line indicators can provide ModBUS interface alarm relay (hysteresys and threshold control) and IP66 case.

Features
  • 3 and 1/2 decimal digit display (2000 spots), red LEDs high brightness, programmable decimal point in every positions. Double ramp conversion with autozero, 3 readings per second.
  • Input :
    • Voltage : 0-2 Vdc , 0,4-2 Vdc , 0-5 Vdc , 1-5 Vdc , input impedance >100Kohm.
    • Current : 0-20 mA and 4-20 mA active (power loop 24 Vdc) or passive connection , input impedance 100ohm.
  • Zero creep better than 1 ppm/°C, SPAN creep better than 50 ppm/°C.
  • Optional boards for PT100 thermo resistors' input (0,2 % of the range precision) or for thermocouple K or T type (0,5 % of the range precision).
  • Optional board for ritransmitted output galvanically isolated , 0-20 mA and 4-20 mA active and passive connection (power loop 24 Vdc).
  • 1 alarm set-point with output wiht relay on S310A type.
  • 2 alarms set-point with output wiht relay on S310AA and S320Atype.
  • Manual alarms regulation in the all range by a trimmer and there is also a button to display the value.
  • It is also possible to set two threshold alarm levels for maximum and minimum operating value.
  • Fixed hysteresis ± 0,5 %. 1 SPDT switch, 5A 250 Vac (resistive load).
  • 2 possible different power supply .115 / 230 Vac ± 10 % 50 / 60 Hz 3,5 VA 24 Vdc-ac ± 10 % isolated dc/dc converter 3,5 VA.
  • Working temperature from -10 to +50 °C, humidity max 90 % at 40 °C( non condensing).
  • ENCLOSURE in"V0" self-extinguishing NORYL, shock-proof cabinet, suitable for frontpanel installation .
  • Size : S310-S310A-S310AA (hlp) 96 x 96 x 148 mm (DIN 43700) S320A(hlp) 96 x 96 x 148 mm (DIN 43700).
  • Drill gauge : S310-S310A-S310AA (hl) 92 x 45 mm, S320A(hl) 90 x 91 mm.

Related items