Specifications |
Technology |
Standards | IEEE 802.3, 802.3u, 802.3x |
Processing Type | Store & forward |
MAC Addresses | 1024 |
Memory Bandwidth | 3.2 Gbps |
Frame buffer memory | 512 Kbit |
Flow Control | IEEE802.3x flow control, back pressure flow control |
Interface |
RJ45 ports | 10/100 Base-T(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection |
Dielectric I/O to Frame | 1500 VDC 1 minute |
MMI (Man Machine Interface) |
LED Indicators | Master, Power, 10/100M, Link/Act |
Rotary Switch | Recovery time setting |
DIP Switch | Switch configuration |
Redundant Power Input |
Input Voltage Range | +12 ~ +48 VDC |
Power consumption | 0.3A@24 VDC |
Reverse polarity protect | Yes |
Dielectric I/O to Frame | 1500 VDC 1 minute |
Connection | 5-Pin Removable Terminal Block(5.08mm) |
Mechanical |
Case | Metal |
Dimensions | 25 mm x 168 mm x 119 mm (W x L x H) |
Installation | DIN-Rail |
Temperature/Humidity |
Operating Temperature | -30 ~ +75°C; Cooling Test (IEC 60571), Dry Heat Test (IEC 60571) |
Storage Temperature | -40 ~ +85°C |
Ambient Relative Humidity | 10% ~ 90% HR, non-condensing |
EMC Emission |
Conducted Emissions | EN 50121-3-2, EN55011 |
Radiated Emissions | EN 50121-3-2, EN55011 |
EMC Immunity |
Electrostatic Discharge | EN 50121-3-2, IEC61000-4-2 |
Radiated, Radio-Frequency, Electromagnetic Field | EN 50121-3-2, IEC61000-4-3 |
Electrical Fast Transient/Burst | EN 50121-3-2, IEC61000-4-4 |
Surges | EN 50121-3-2, IEC61000-4-5, IEC 60571 |
Conducted Disturbance Induced by Radio-Frequency Field | EN 50121-3-2, IEC61000-4-6 |
Vibrations |
Random Vibration test | IEC 61373 |
Shock Testing | IEC 61373 |