SPECIFICATIONS |
| GENERAL |
| Output | 4-20 mA (two-wire, on power loop) |
| Accuracy | ± 1% of reading or ± 1°C whichever is greater |
| Repeatability | ± 0.5% of reading or ± 0.5°C whichever is greater |
| Emissivity Setting | Adjustable from 0.2 to 1.0 via 4-20 mA input |
| Response Time, t9 | 0240 ms (90% response) |
| Spectral Range | 8 to 14 µm |
| Supply Voltage | 24 V DC (28 V DC max.) |
| Min. Sensor Voltage | 6 V DC |
| Max. Loop Impedance | 900 O (4-20 mA output) |
| Input Impedance | 50 O |
| PyroTune Emissivity Adjuster Specifications |
| Output | 4-20 mA |
| Supply Voltage | 24 V DC (13 V to 28 V DC) |
| Display Format | 3.5 digit LCD |
| Display Units | Emissivity (0.2 to 1.0) or current (4 to 20 mA) |
| Adjustment | Push-buttons (raise/lower/set) |
| Construction | Polycarbonate with gasket, transparent lid (PC) and quick release screws |
| Mounting | Surface |
| Dimensions | 65(h) x 50(w) x 35(d) mm |
| Weight | 72 g |
| Environmental Rating | IP65 |
| Ambient Temperature Range | 0°C to 70°C |
| Relative Humidity | 95% max. non-condensing |
| Mechanical Specifications |
| Construction | Stainless Steel |
| Dimensions | Diameter 18 mm diameter x length 103 mm |
| Thread Mounting | M16 x 1 mm pitch |
| Cable Length | 1 m (longer lengths available to order) |
| Weight with Cable | 95 g |
| Environmental Specifications |
| Environmental Rating | IP65 |
| Ambient Temperature Range | 0°C to 70°C |
| Relative Humidity | 95% max. non-condensing |