Technical data |
EMS Protection |
ESD (IEC 61000-4-2) | ± 4 kV Contact |
LED Indicators |
Status | PWR1, PWR2, PWR_Fault, PWR_OK, Link/Act, 10/100M |
Ethernet |
Ports | 4 x RJ-45, 10/100Base-TX |
Standards | IEEE 802.3, 802.3u, 802.3x |
Processing Type | Store & forward; wire speed switching |
MAC Addresses | 1024 |
Memory Bandwidth | 1.6 Gbps |
Frame Buffer Memory | 256 Kbit |
Flow Control | IEEE 802.3x flow control, back pressure flow control |
Isolation | 1500 Vrms 1 minute |
Fiber |
Ports | 2 x 100 Base-FX, ST connector |
Mode Multi-Mode |
Fiber Cable | 50/125, 62.5/125 or 100/140 gm |
Distance | 2 km, (62.5/125 gm recommended) for full duplex |
Wavelength | 1300 or 1310nm |
TX Output | -20 dBm Min. -14 dBm Max. |
RX Sensitivity | -34 dBm |
Power |
Reverse Polarity Protection | Yes |
Input Range | +10 ~ +30 VDC (Redundant input) |
Redundant Power Inputs | Yes |
Consumption | 0.2 A @ 24 VDC |
Alarm Contact | Yes, Relay 1 A @ 30 VDC |
Mechanical |
Casing | Metal |
Dimensions (mm) | 73 x 132 x 105 (W x L x H) |
Installation | DIN-rail mounting or wall mounting |
Ingress Protection Rating | IP20 |
Environmental |
Operating Temperature | 0 °C ~ +70 °C |
Storage Temperature | -20 °C ~ +85 °C |
Humidity | 10% ~ 90% RH, non-condensing |