Specifications |
Models | NS-205PSE-24V | NSM-205PSE-24V |
Technology |
Standards | IEEE 802.3, 802.3u, 802.3x ,802.3af (Power over Ethernet) |
Processing Type | Store & forward, wire speed switching |
MAC Addresses | 1024 |
Memory Bandwidth | 3.2 Gbps |
Frame Buffer Memory | 512 Kbit |
Flow Control | IEEE802.3x flow control, back pressure flow control |
Interface |
RJ-45 Ports | 10/100 Base-T(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection |
LED Indicators | Power, Link/Act , 10/100M, Power Device is detected |
Ethernet Isolation | 1500 Vrms 1 minute |
+/-6 kV EMS Protection | Yes |
Power Input |
Input Voltage Range | +18 ~ +32VDC for PoE output |
Power Consumption | 0.24@ 24 VDC with PoE Off |
Protection | Power reverse polarity protection |
+/- 6kV EMS Protection | Yes |
Connection | 3-Pin Removable Terminal Block |
PoE Output (Port1 ~ 4) |
PoE Compliance | 100% IEEE 802.3af compliant |
PoE Classification | PSE (Power Sourcing Equipment) |
PoE Voltage | +48 VDC depending on power input |
PoE Power | Up to 15.4 watts per channel |
PoE Operation | Automatic detection and power management |
Mechanical |
Casing | Plastic (Flammability UL 94V-0) | Metal (IP30 Protection) |
Dimensions | (W x L x H) 31 mm x 157 mm x 113 mm | 25 mm x 168 mm x 119 mm |
Installation | DIN-Rail |
Environment |
Operating Temperature | -40°C ~ +75°C |
Storage Temperature | -40°C ~ +85°C |
Humidity | 10% to 90% RH, non-condensing |