8 Up Counter/Frequency Channels or 4 Encoder Input Channels. RS-485 interface supports Modbus RTU and DCON protocols, includes free EZ Data Logger software for data logging. DIN Rail mounting. Requieres 10 to 30Vdc power supply. The M-7084 is a 32-bit high-speed Counter/Frequency/Encoder input module that offers a variety of mode options, including "Up Counter”, "Frequency Input", "Up/Down Counter", "Direct/Pulse Counter" and "A/B Phase Counter" modes. The mode combinations can be individual set for all 8 channels, where some channels can be set to “Up Counter” mode and other channels can be simultaneously set to “Frequency”, "Up/ Down Counter" or “Encoder input” mode. The built-in digital filter can filter out noise where the high/ low pulse width is smaller than the minimum high/low width of the digital filter. The M-7084 provides a virtual battery backup function in counter mode.
Features:
- 8 Up Counter/Frequency Channels or 4 Encoder Input Channels
- Programmable Digital Filter
- 32-bit Counter
- Individual Channel Configuration
- Virtual Battery Backup to Preserve Counter Values
- +/-4 kV ESD Protection
- Preset Values for Counter Input
- RoHS Compliant
- Wide Operating Temperature Range: -25 ~ +75°C