Specifications |
ANALOG SECTION |
Excitation voltage | 10V DC ± 5%, output current within 120mA Remote sensing (Up to four 350 load cells can be connected in parallel.) |
Zero adjustment range | 0 - approx. 2mV/V |
Gain adjustment range | 0.3 - 2.0V/V |
Signal input range | 0.0 - 2.0V/V |
Minimum input sensitivity | |
Accuracy | Non-linearity: within 0.01%FS (Typ 0.005%/FS Normal temperature) Zero drift: within 0.1μV/ ℃RTI(Typ 0.08μV/℃) Gain drift: within 15ppm/℃(Typ 5ppm/℃) |
Analog filter | Bessel low-pass filter-12dB/oct, cutoff frequency 2/ 4/ 6/ 8Hz |
A/D converter | Rate:1000times/sec Resolution:24bit(binary) |
SETTING SECTION |
Setting item | ●Final / Set point 1 / Set point 2 / Compensation (CPS) / Over / Under / Upper limit / Lower limit / Near zero / Preset tare value ●Comparison inhibit time / Judging time / Complete output time / Adjust feeding time / Auto zero times / Judging times / Auto free fall compensation coefficient / Average count of auto free fall compensation / Auto free fall compensation regulation ●Over/Under comparison / Upper/Lower limit comparison / Near zero comparison / Feed/discharge control mode / Preset tare weight / Auto free fall compensation / Complete output mode / Over/Under comparison mode / Upper/Lower limit comparison mode / Net weight sign inversion in discharge weighing ●Digital filter / Motion detection (period) / Motion detection (range) / Zero tracking (period) / Zero tracking (range) / Analog filter / Filter in a stable condition / Motion detection mode / Option setting(None, BCD, CC-Link) / SI/F G/N selection ●Balance weight / Capacity / Minimum scale division / Net over / Gross over / Digital zero regulation value / Decimal place / Gravitational acceleration / Calibration value LOCK (SOFT LOCK) / Set value LOCK (SOFT LOCK) ●Simple comparison / Sequence mode selection / Adjust feeding in sequence mode / Near zero check in sequence mode / Weight value check in sequence mode ●External control output selection 0 / External control output selection 1 / External control output selection 2 / External control output selection 3 / External control output selection 4 / External control output selection 5 / External control output selection 6 ●External control input selection 0 / External control input selection 1 / External control input selection 2 / External control input selection 3 / External control input selection 4 ●Tare subtraction / Tare reset / Digital zero / Digital zero reset / Sequence start / Sequence stop / Sequence error reset ●Zero calibration / Actual load calibration / Equivalent input calibration (rated output value) / Password |
INPUT/OUTPUT SECTION |
External output signal (7 points) | Each control output is selectable by setting. Near Zero, SP1, SP2, SP3, Under, Go, Over, Complete, Normally OFF, Lower Limit, Upper Limit, Stable, Weight Alarm, Sequence Error, Final Error, In Operation (RUN), Clock (in an approximately one-second cycles) Transistor open collector output (sink type)ON when the transistor is ON Vce = 30V (Max), Ic = 50mA (Max) |
External Input signal (5 points) | Each control input is selectable by setting. Digital Zero Reset, Digital Zero, Tare Subtraction, Tare Reset, HOLD or Judge, Feed/Discharge, Sequence Start, Sequence Stop, No Function ON when short-circuited with the COM terminal.(Dry contact type) |
INTERFACE | SIF:SI/F 2-wire serial interface (Standard)……This is a simple output serial interface for connection of a UNIPULSE-manufactured printer, external display, etc. BCO:BCD parallel data output interface(Option)Transmits weight data to a PLC or other BCD devices. CCL:CC-Link interface(Option)……Serial bus interface for connection with PLC |
DISPLAY SECTION |
Display unit | Character height 8mm 7-segment red LED, 6 digits |
Measured value | 5digits: -99999 - +99999 |
Sign | Minus sign on most significant digit |
Decimal point | 0, 0.0, 0.00, 0.000 selective |
Display frequency | 25times/sec. (Speed of system 1000 times/sec.) |
GENERAL SPECIFICATIONS |
Power supply voltage | DC24V (15%) |
Power consumption | 10W(Max) |
Operating conditions | Temperature: Operating temperature range -10℃ to +40℃ Storage temperature range -20℃ to +80℃ Humidity:85%RH or less (non-condensing) |
Dimensions | 67(W)×185(H)×120(D) (mm) (excluding projections) |
Weight | Approx. 1.2kg |
ACCESSORIES |
Control signal Input/Output connector | 1 |
Jumper cable | 2 |
Wall anchor (It attached main body.) | 2 |
Operation manual | 1 |
Connector for BCD output (with BCD option) | 1 |
Connector for CC-Link (with CC-Link option) | 1 |