Specifications |
SUPPLY VOLTAGE |
12 to 30 VDC Polarity Protected |
CURRENT REQUIREMENTS |
95mA @ 12 VDC, 45mA @ 30 VDC |
DIGITAL OUTPUTS |
(1) NPN and (1) PNP open collector output 150mA Max; < 2V Residual Voltage All outputs are continuously short circuit protected |
REMOTE AUTOSET INPUT |
Momentary sinking or sourcing input; 1.2mA max; Software Selectable |
DIAGNOSTIC INDICATORS |
OLED Graphic Display - Includes Contrast Indicator, Numerical Display, Set Point and Trigger Point, and all sensor options and modes. Red LED Output Indicator– Illuminates when the sensor’s output transistors are “ON”. |
PUSHBUTTON CONTROL |
Three (3) push button controls Gap (for Gap AUTOSET) Label (for multi-layered labels) Menu (for accessing Options) |
HYSTERESIS |
Dynamic – adjusted by AUTOSET |
RESPONSE TIME |
200µs |
REPEATABILITY |
125µs |
AMBIENT TEMPERATURE |
4°C to 50°C (39°F to 122°F) |
RUGGED CONSTRUCTION |
Chemical resistant, high impact Aluminum housing Waterproof ratings: NEMA 4X, 6P and IP65 Conforms to heavy industry grade CE requirements |
THRESHOLD SET |
1-Point, 2-Point, or Dynamic AUTOSET; manually or remotely. |
THRESHOLD ADJUST |
Manual or AUTO Adjust |
OUTPUT TIMERS |
On Delay, Off Delay, One Shot, or Debounce (Advanced Option, software selectable). |
CONNECTOR |
M12 5-Pin, M8 4-Pin, or 6’ (1.8m) Shielded Cable |