TECHNICAL SPECIFICATIONS |
Relay specifications |
Number of relays |
8 |
Relay configuration |
2 banks of 4 |
Contact configuration |
8 Form C (SPDT) Normally Open, Normally Closed and Common available at screw terminals |
Contact rating |
5 A @ 240 VAC or 28 VDC resistive |
Contact resistance |
100 mO max (initial value) |
Operate time |
10 ms max |
Release time |
5 ms max |
Vibration |
10 Hz to 55 Hz (amplitude 1.5 mm) |
Shock |
10 G (11 ms) |
Dielectric isolation (between relay open contact) |
300 VAC, 50/60 Hz (1 minute) |
Dielectric isolation (between PCB output lines) |
500 VAC, 50/60 Hz (1 minute) |
Life expectancy |
10 million mechanical operations, min |
Power on state S2 = pull-up Energized. S2 = pull-down |
Not energized. NC in contact to Common NO in contact with Common |
Relay control logic polarity |
User-configurable per bank via switch S1 for invert or non-invert (default). Switch settings for polarity can be read back via software through the USB bus. Switch settings do not affect the power on condition. |
Pull-up/pull-down (controls relay power on state) |
User-configurable per bank via switch S2 for pull-down (default) or pull-up. Switch settings can be read back via software. |
Power |
USB +5 V input voltage range |
4.75 V min. to 5.25 V max. |
USB +5 V supply current |
10 mA max |
External power supply (required) |
9 V ±10% @ 1 A |
External power input |
+6.0 VDC to 12.5 VDC (9 VDC power supply included) |
Voltage supervisor limits PWR LED |
LED = Off (power fault) PWR LED = On |
External power adapter (included) |
+9 V ±10%, @ 1 A |