SPECIFICATIONS |
Parameter | Condition | Specification |
A/D converter type | | Delta-Sigma |
A/D resolution | | 24-bit |
Number of channels | | 32 |
Filtering options | | 50 Hz or 60 Hz noise filtering, softwareselectable |
Isolation | Between any TCx channel and chassis ground. | 500 VDC absolute max |
Channel configuration | | Software-selectable to match thermocouple sensor type |
Differential input voltage range | | ±78.125 mV |
Absolute maximum input voltage | Between any two TCx inputs | ±25 V (power on) ±25 V (power off) |
Differential input impedance | 50 Hz filtering, power on | 26 M? |
60 Hz filtering, power on | 20 M? |
Input current | Open thermocouple detect disabled | 2 nA |
Open thermocouple detect enabled | 75 nA |
Common mode rejection | 50 Hz filtering, at DC and fin=50 Hz | 110 dB |
60 Hz filtering at DC and fin=60 Hz | 110 dB |
Noise rejection | 50 Hz filtering at fin =50 Hz | 80 dB typ. |
60 Hz filtering at fin =60 Hz | 80 dB typ. |
Input bandwidth | 50 Hz filtering | 22 Hz |
60 Hz filtering | 26 Hz |
Crosstalk | Between any two TCx inputs | -90 dB |
Sample rate | | 3 Hz max (per channel) |
Common mode voltage range | TCx channel to TCx channel | ±1.40 V |
TCx channel relative to chassis ground, fin = 60 Hz | ±3.5 VAC p-p |
TCx channel relative to chassis ground | ±48 VDC |
Input noise | 50 Hz or 60 Hz filtering | 510 nV rms |
Gain error | 50 Hz or 60 Hz filtering | 0.004 % |
Offset error | 50 Hz or 60 Hz filtering | 3 µV |
Measurement sensitivity | Thermocouple type J,K,T,E,N | 0.05 °C |
Thermocouple type R,S | 0.10 °C |
Thermocouple type B | 0.15 °C |
Warm-up time | | 20 minutes min |
Open thermocouple detect response time | | 1 second |
CJC sensor accuracy | °C to 45 °C | ±0.20 °C typ ±0.40 °C max |
Calibration method | | Factory |
Recommended warm-up time | | 20 minutes min |
Calibration interval | | 1 year (factory calibration) |